You don’t usually book central heating repairs because the boiler is “dead”. You book them because the house feels oddly patchy, the radiators take ages, and you’re quietly watching the pressure gauge like it owes you money. A huge chunk of the time, pump circulation problems are the real villain - the system can’t move hot water properly, so everything else looks guilty.
I saw it last winter in a terrace in Sheffield. The homeowner had already priced up a new boiler after three weeks of lukewarm radiators and that thin, constant hum of anxiety. When we opened the cupboard, the boiler was doing its job. The heat just wasn’t getting where it needed to go.
The moment you realise it’s not “no heat” - it’s no movement
Boilers make heat. Pumps move it. If the pump can’t circulate, you can have a perfectly capable boiler and a house that still feels like a compromise: one radiator roasting, another stone cold, and a bathroom towel rail that behaves only when it feels like it.
The giveaway is the pattern. True boiler faults tend to be dramatic - lockouts, error codes, a total lack of hot water. Circulation faults are sneakier. They show up as inconsistency, and they get worse when you need the system most.
Common signs that point to circulation, not combustion:
- Radiators warm at the top but cold at the bottom (or vice versa).
- Upstairs heats, downstairs sulks (or the other way round).
- The boiler fires up, then shuts down quickly (“cycling”) because heat can’t shift away.
- You can hear gurgling, rushing, or a persistent buzzing near the pump.
- Bleeding helps for a day, then the cold spots return.
What’s actually happening inside the pipes
Most UK wet central heating systems rely on a small circulation pump to push hot water from the boiler through radiators and back again. If flow is restricted, the boiler’s heat has nowhere to go, so it either throttles back, trips, or keeps starting and stopping in short bursts. You feel it as rooms that never quite settle.
A few usual suspects turn up again and again. Some are mechanical, some are “system hygiene”, and some are simply settings that drifted over time.
The big three culprits (and why they fool people)
1) Air and poor bleeding habits.
Air locks can stall flow entirely in parts of the system, especially after recent work, a drain-down, or a slow leak that keeps introducing fresh air. People bleed the radiators, get a satisfying hiss, and assume they’ve “fixed it” - but if air keeps re-entering, you’re just bailing water.
2) Sludge and magnetite.
That black, gritty stuff doesn’t just make radiators less efficient; it can choke narrow sections, jam pump impellers, and clog strainers. A boiler may be new, but if the system water is filthy, it’s like putting a fresh engine into a car with a blocked fuel line.
3) A tired or incorrectly set pump.
Some pumps fail loudly. Others just weaken. And many modern pumps have speed or pressure settings that can be wrong for the property - especially if radiators were added, pipework altered, or a previous “quick fix” left it on a setting that sounded quieter but circulates worse.
The quick checks that save you from buying the wrong thing
There’s a reason decent engineers ask a lot of questions before they condemn a boiler. Circulation issues often show themselves in simple observations - the sort you can do with a hand on a radiator and a little patience.
A practical sequence that often clarifies the picture:
- Check pressure (combi systems): if it’s low, fix that first - low pressure can mimic circulation trouble.
- Feel the flow and return pipes near the boiler: if flow gets hot fast but return stays cool, heat isn’t travelling.
- Listen when the heating first fires: gurgling and rushing suggest air; a strained whine can point to the pump.
- Compare radiators: if the nearest ones heat and the farthest don’t, think balancing/flow restriction.
- Look for a magnetic filter: if there is one, it may be full; if there isn’t, sludge has been touring the system unchecked.
None of this replaces proper diagnosis, but it stops the classic mistake: replacing a boiler when the system around it is the real issue.
What central heating repairs look like when circulation is the problem
When an engineer treats this properly, it’s rarely one magic tweak. It’s a small, sensible chain of actions that restores flow, then protects it so the same problem doesn’t creep back in.
Typical fixes (depending on what’s found):
- Bleeding and venting properly, then checking for the reason air is appearing (leaks, failed auto air vent, poor fill procedure).
- Cleaning strainers and filters, especially if the system has been noisy or recently refilled.
- Balancing radiators, so water doesn’t take the lazy route through the easiest loop and ignore the rest of the house.
- Pump inspection/replacement, if it’s seized, noisy, weak, or incorrectly sized for the system.
- Powerflushing or targeted flushing, when sludge is clearly restricting flow.
- Adding inhibitor and a magnetic filter, because clean flow today is pointless if you let corrosion rebuild tomorrow.
“Most ‘my boiler’s dying’ call-outs I go to are really ‘my system’s not circulating’ call-outs,” says one long-standing heating engineer I spoke to in Manchester. “The boiler’s the headline. The pipes are the story.”
The calm payoff: even heat, fewer cycles, less stress
When circulation is restored, the difference feels almost unfairly simple. Radiators heat together, rooms stop playing favourites, and the boiler runs in longer, steadier stretches rather than frantic bursts. The house feels quieter too - less rushing water, fewer clicks, less of that constant sense that you’re fighting the system.
And crucially, you stop spending money in the wrong place. A new boiler can be brilliant when you need one. But if the real fault is pump circulation problems, the best “upgrade” is often a clean, correctly set system that actually moves heat.
| Clue you notice | Likely issue | What a repair targets |
|---|---|---|
| Patchy radiators, frequent cycling | Restricted flow | Balancing, clearing restrictions, pump checks |
| Gurgling, needs bleeding often | Air entering/air lock | Venting, leak checks, auto-vent faults |
| Noisy pump, hot flow/cool return | Weak or stuck circulation | Pump service/replacement, filter clean |
FAQ:
- Can a boiler still make hot water if circulation is bad? Yes. Hot water and heating often behave differently, especially on combi boilers. You can have great showers and miserable radiators if heating flow is the issue.
- Is it safe to keep running the heating like this? It’s usually not an immediate danger, but it can increase wear: more cycling, more stress, and a higher chance of nuisance lockouts. Get it diagnosed sooner rather than later.
- Will bleeding radiators fix pump circulation problems? Sometimes it helps if air is the main restriction, but repeated bleeding often means air is re-entering or sludge is interfering with flow. Treat the cause, not just the symptom.
- Do I need a powerflush every time? No. Some systems need a full powerflush; others respond to cleaning the filter, flushing a problem radiator, or adding inhibitor. A good engineer should justify it based on evidence.
- How do I stop it happening again? Keep inhibitor topped up, clean the magnetic filter (if fitted), address small leaks promptly, and don’t ignore new noises - they’re often the first hint that flow is starting to suffer again.